Batch Control/Stroke Counter Page 7Batch-sc-rev0611
520-180-000 3/02 Batch Control / Stroke Counter Page 7
Wiring Diagram
Connecting the control box to other
system components.
®SandPIPER,RuppTechandWarrenRuppareregisteredtradenamesofWarrenRupp,Inc.
©2002WarrenRupp,Inc.Allrightsreserved.
IMPORTANT!
If installing other RuppTech components,
such as the Pulse Output Kit or Solenoid Kit,
please refer to the separate service pages supplied
with the items.
NOTE: Use a momentary con-
tact switch when using a remote
start/stop control.
Wiring Diagram for Interface
with 249-006-000 Batch Control / Stroke Counter (Non-Hazardous Location)
SandPIPER Air Valve
Mounted to Pump
Power Input
#22 AWG Cable
Terminal #1
Neutral (Positive)
3rd Terminal
for ground
Terminal #2
Power (Negative)
21
Customer Supplied
Remote Control
Momentary Switch
Solenoid
Air Valve
Output Channel #2
4
3
2
1
(+) Common
(-) Ground
Output Channel #1
GROUND
CHASSIS GROUND
PROXIMITY SENSOR INPUT(S)
24VDC
STOP SWITCH
100-120VAC
START SWITCH
RELAY OUTPUT COMMON
RELAY OUTPUT (+)
100-240VAC
COMMON GROUND
NEUTRAL
POWER 100-240VAC
Stroke counter/Batch Control
STOP
RESET
PRESET
COUNT
DIGIT
SELECT
TOTAL
COUNT
START
IDEX CORPORATION
INCREASE
DIGIT
WARREN RUPP PUMP CONTROLS