Panel Button Functions
BUTTON ....................................... FUNCTION(S)
Total Count .................................. Display the total or accumulated count.
Digit Select/Reset ....................... Resets the count displayed
(Preset or Total).
Preset Count ............................... Displays the batch size.
Press and hold: Total Count
then press: Increase Digit ........... Moves decimal point.
Press at the same time and hold:
Total Count + Preset Count
then press: Digit Select Selects digit for programming Stroke
Scale Valve. Selected digit will flash.
then press: Increase Digit ........... To program valve to the selected
(flashing) digit.
Increase Digit .............................. Increases value of selected (flashing)
digit. --ALSO-- Selects storage register
for program storage. (P0-P9)
Programming & Set-up Functions (with pump stopped)
Setting the Multiplier or Stroke Scale Value
Eachinputsignal fromthe PulseOutput Interfacemounted onthe pump
registersonecountintothecontrol.Thevalueofthiscountmustbedetermined
at the initial set-up for display purposes. For example, to count only pump
strokes,theStrokeScaleValuewouldbesetat1(one).Onepulsewouldequal
onestroke.
To settheStrokeScaleValue,simultaneously presstheTotal Count and
PresetCountbuttonsinandhold.ThenusetheIncreaseDigitbuttontoenterthe
valueassignedtotheashingdigit.Toprogram,thedigittothefarrightofthe
displayshouldbeashing.Ifitisnotashing,presstheDigitSelectbuttonuntil
thedigittobeprogrammedbeginstoash.Thedecimalpointshouldbetothe
farright.
Moving the Decimal Point for Fractional Volumes
Ifthevalueyouwishtouseisafractionalvolume,suchasdisplacementper
pumpstroke,thedecimalpointmustbemovedintotheproperlocationBEFORE
aStrokeScaleValueisentered.
WhilepressingtheTotalCountbutton,pressandreleasetheIncreaseDigit
buttonuntildecimalpointisinposition.AstheIncreaseDigitbuttonispressed
andreleased,thedecimalpointlocationwill
movefromrighttoleftonthedis-
play.PressandreleaseIncreaseDigit,untilthedecimalpointisinthedesired
position.
Once the decimal point is positioned, set the Stroke ScaleValue.These
instructionsappearintheprevioussection.Also,pleaserefertotheprogramming
andtestingproceduresoutlinedearlierinthismanualfordetailedinstructions.
Thesectionisentitled,ProgrammingforAccuracy.
PROGRAMMING QUICK
REFERENCE
Setting the Decimal Point
1.PressandholdTotalCount.
a.Repeatedlypressandrelease
IncreaseDigittomovedecimal
pointfromrighttoleft.
Setting the Multiplier or Stroke Scale
1. Pressandhold:
TotalCount+PresetCount.
a.PressandreleaseDigitSelect
untildigitashes.
b.PressIncreaseDigitto
programtheashingdigit.