Sandpiper S1F Non-Metallic Bedienungsanleitung Seite 1

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Pumpen Sandpiper S1F Non-Metallic herunter. SANDPIPER S1F Non-Metallic User Manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 33
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
WARREN RUPP
®
, INC. • A Unit of IDEX Corporation • P.O. Box 1568, Mansfield, Ohio 44901-1568 USA • Telephone (419) 524-8388 • Fax (419) 522-7867 • www.warrenrupp.com
520-199-000 1/01
©Copyright 2000 Warren Rupp, Inc. All rights reserved.
SERVICE & OPERATING MANUAL
Model S1F Non-Metallic Design Level 2
Engineering Data and Temperature Limitations ...................................................................... 1
Explanation of Pump Nomenclature ........................................................................................ 2
Performance Curve, Model S1F Non-Metallic Design Level 2 ............................................... 3
Dimensions: S1F Non-Metallic ................................................................................................. 4
Metric Dimensions: S1F Non-Metallic ..................................................................................... 5
Dimensions: S1F Non-Metallic with Spill Prevention ................................................................ 6
Metric Dimensions: S1F Non-Metallic with Spill Prevention .................................................... 7
Principle of Pump Operation .................................................................................................... 8
Installation and Start-up ........................................................................................................... 8
Air Supply ................................................................................................................................. 8
Air Valve Lubrication ................................................................................................................. 8
Air Line Moisture ...................................................................................................................... 8
Air Inlet and Priming ................................................................................................................. 8
Between Uses .......................................................................................................................... 8
Installation Guide ...................................................................................................................... 9
Important Safety Information ................................................................................................. 10
Material Codes ....................................................................................................................... 10
Troubleshooting ...................................................................................................................... 11
Warranty ................................................................................................................................. 11
Composite Repair Parts Drawing .......................................................................................... 12
Overlay Option Drawing ........................................................................................................ 1 2
Composite Repair Parts List .................................................................................................. 13
RuppGUARD™ Spill Prevention Option for Virgin PTFE Equipped Pumps ......................... 14
RuppGUARD™ Spill Prevention Repair Parts List ............................................................... 14
RuppGUARD™ Spill Prevention Concept............................................................................. 15
RuppGUARD™ Spill Prevention Option Diaphragm Servicing ............................................ 15
Filling RuppGUARD™ Chambers with Liquid ....................................................................... 15
RuppGUARD™ Spill Prevention Option for TPE Equipped Pumps ..................................... 16
RuppGUARD™ Spill Prevention Repair Parts List ............................................................... 16
RuppGUARD™ Spill Prevention Concept with TPE Diaphragms ........................................ 17
RuppGUARD™ Spill Prevention Option with TPE Diaphragm ............................................. 17
Air Distribution Valve Assembly Drawing ............................................................................... 18
Main Air Valve Assembly Parts List ....................................................................................... 18
Air Distribution Valve Servicing .............................................................................................. 19
Air Distribution Valve with Stroke Indicator Options .............................................................. 20
Air Distribution Valve with Stroke Indicator Parts List ........................................................... 20
Air Distribution Valve with Stroke Indicator Servicing ........................................................... 21
Pilot Valve Assembly Drawing ................................................................................................ 22
Pilot Valve Assembly Parts List.............................................................................................. 22
Pilot Valve Servicing ............................................................................................................... 23
Diaphragm Service Drawing, Non-Overlay .......................................................................... 24
Diaphragm Service Drawing, with Overlay ........................................................................... 24
Diaphragm Servicing .............................................................................................................. 25
Overlay Diaphragm Service .................................................................................................. 25
Pumping Hazardous Liquids .................................................................................................. 26
Converting the pump for piping the exhaust air .................................................................... 26
Exhaust Conversion Drawing ................................................................................................ 26
Converted Exhaust Illustration .............................................................................................. 26
Modular Check Valve Servicing ............................................................................................. 27
Modular Check Valve Drawing............................................................................................... 27
Dual Port Option Drawing ...................................................................................................... 28
Dual Porting Options .............................................................................................................. 29
Dual porting of both suction and discharge ends of the pump ............................................. 29
Single porting of the suction and dual porting of the pump discharge.................................. 29
Dual porting of the suction and single porting of the pump discharge ................................. 29
Leak Detection Options Drawing........................................................................................... 30
RuppTech® Electronic Leak Detector Installation ................................................................ 30
Mechanical Leak Detector Installation .................................................................................. 30
RuppTech® Pulse Output Kit Drawing .................................................................................. 31
RuppTech® Pulse Output Kit Option ..................................................................................... 31
Exhaust Port or Auxiliary Muffler Setup ................................................................................. 31
Integral Muffler Setup ............................................................................................................. 31
Table of Contents
CE
U.S. Patent #
400,210
5,996,627
Seitenansicht 0
1 2 3 4 5 6 ... 32 33

Inhaltsverzeichnis

Seite 1 - Table of Contents

WARREN RUPP®, INC. • A Unit of IDEX Corporation • P.O. Box 1568, Mansfield, Ohio 44901-1568 USA • Telephone (419) 524-8388 • Fax (419) 522-786

Seite 2

520-199-000 1/01 Model S1F Non-Metallic Design Level 2 Page 8PRINCIPLE OF PUMP OPERATIONThis ball typ

Seite 3 - S1F Non-Metallic

520-199-000 1/01 Model S1F Non-Metallic Design Level 2 Page 912341234Surge Suppressor020-050-000 Filt

Seite 4

520-199-000 1/01 Model S1F Non-Metallic Design Level 2 Page 10MATERIAL CODESThe Last 3 Digits of Part

Seite 5 - Design Level 2

520-199-000 1/01 Model S1F Non-Metallic Design Level 2 Page 11TROUBLESHOOTINGPossible Symptoms:• Pump

Seite 6 - Dimensions: S1F Non-Metallic

520-199-000 1/01 Model S1F Non-Metallic Design Level 2 Page 12Overlay Option DrawingMuffler OptionDra

Seite 7

520-199-000 1/01 Model S1F Non-Metallic Design Level 2 Page 13Composite Repair Parts ListITEM PART NU

Seite 8

520-199-000 1/01 Model S1F Non-Metallic Design Level 2 Page 14RuppGUARD™ Option forVirgin PTFE Equipp

Seite 9 - Mesh Muffler 167mm 283mm

520-199-000 1/01 Model S1F Non-Metallic Design Level 2 Page 15RuppGUARD™ FOR VIRGIN PTFEEQUIPPED PUM

Seite 10

520-199-000 1/01 Model S1F Non-Metallic Design Level 2 Page 16RuppGUARD™ Option for TPEEquipped Pumps

Seite 11 - INSTALLATION GUIDE

520-199-000 1/01 Model S1F Non-Metallic Design Level 2 Page 17RuppGUARD™ FOR TPEEQUIPPED PUMPS CONC

Seite 13 - • Pump cycle seems to produce

520-199-000 1/01 Model S1F Non-Metallic Design Level 2 Page 18Air Distribution Valve Assembly Drawing

Seite 14 - Muffler Option

520-199-000 1/01 Model S1F Non-Metallic Design Level 2 Page 19AIR DISTRIBUTION VALVESERVICINGTo servi

Seite 15 - Composite Repair Parts List

520-199-000 1/01 Model S1F Non-Metallic Design Level 2 Page 20Air Valve Assembly Drawing with Stroke

Seite 16 - Pumps Drawing

520-199-000 1/01 Model S1F Non-Metallic Design Level 2 Page 21Read these instructionscompletely, befo

Seite 17 - IMPORTANT

520-199-000 1/01 Model S1F Non-Metallic Design Level 2 Page 22Pilot Valve Assembly Parts ListItem Par

Seite 18 - Equipped Pumps Drawing

520-199-000 1/01 Model S1F Non-Metallic Design Level 2 Page 23Read these instructionscompletely, befo

Seite 19

520-199-000 1/01 Model S1F Non-Metallic Design Level 2 Page 24Diaphragm Service Drawing,Non-OverlayDi

Seite 20 - S1F Design Level 2

520-199-000 1/01 Model S1F Non-Metallic Design Level 2 Page 25DIAPHRAGM SERVICINGTo service the diaph

Seite 21

520-199-000 1/01 Model S1F Non-Metallic Design Level 2 Page 26SAFE AIREXHAUSTDISPOSALAREAPUMP INSTALL

Seite 22

520-199-000 1/01 Model S1F Non-Metallic Design Level 2 Page 27Modular Check Valve DrawingMODULAR CHEC

Seite 23

520-199-000 1/01 Model S1F Non-Metallic Design Level 2 Page 1Quality SystemISO9001 CertifiedEnvironme

Seite 24 - Pilot Valve Assembly Drawing

520-199-000 1/01 Model S1F Non-Metallic Design Level 2 Page 28Dual Port Option Drawing1" ANSI ST

Seite 25

520-199-000 1/01 Model S1F Non-Metallic Design Level 2 Page 29DUAL PORTING OPTIONSSeveral dual portin

Seite 26 - Non-Overlay

520-199-000 1/01 Model S1F Non-Metallic Design Level 2 Page 30Leak Detection Options DrawingRuppTech®

Seite 27

520-199-000 1/01 Model S1F Non-Metallic Design Level 2 Page 31PULSE OUTPUT KIT OPTIONThis pump can be

Seite 28 - Exhaust Conversion Drawing

520-199-000 1/01 Model S1F Non-Metallic Design Level 2 Page 2Pump BrandS= SandPIPER II®Pump Size1F=1&

Seite 29 - Modular Check Valve Drawing

520-199-000 1/01 Model S1F Non-Metallic Design Level 2 Page 35 (8.5)10 (17)20 (34)30 (51)45 (76.5)15

Seite 30 - Dual Port Option Drawing

520-199-000 1/01 Model S1F Non-Metallic Design Level 2 Page 4Dimensions: S1F Non-MetallicDimensions i

Seite 31

520-199-000 1/01 Model S1F Non-Metallic Design Level 2 Page 5Metric Dimensions: S1F Non-MetallicDimen

Seite 32 - MUFFLER CAP

520-199-000 1/01 Model S1F Non-Metallic Design Level 2 Page 6Dimensions: S1F Non-Metallicwith RuppGua

Seite 33 - Integral Muffler Setup

520-199-000 1/01 Model S1F Non-Metallic Design Level 2 Page 7Metric Dimensions: S1F Non-Metallicwith

Kommentare zu diesen Handbüchern

Keine Kommentare